Air dryer — Mattei MD20
Refrigerated air dryer that removes moisture from the compressed air system. It cools the air so water condenses and drains away, then reheats it before it leaves.
Mattei MD20 in the compressor room
Location | Compressor room, beside the storage room |
Access | Maintainers only |
Serial number | 220010311 |
Installed | May 2022 |
Operation
The dryer runs whenever the air supply is in use. Keep the air inlet and hot-air outlet clear.
After a full shutdown, start the dryer first, wait a few minutes, check the dew-point indicator and drainage, then start the compressor.
Leave it off for at least 5 minutes before restarting it.
Report a high dew-point reading, water downstream, leaks, abnormal noise or a drain that isn't working.
A flashing
srvis a service reminder. Do the service rather than just clearing the reminder. One was reported on 31 May 2026; it has not been recorded as done.
Maintenance
Follow §6.1 of the manual: daily dew-point, drain and condenser checks; cleaning every 200 hours or monthly; annual service. Isolate power and air first and let hot parts cool. Clean the condenser with air at max. 2 bar, without bending the fins. Refrigerant and electrical work need qualified personnel.
Specifications
From the MD range catalogue:
Air throughput | 2 m³/min at 7 bar, 25 °C ambient, 35 °C inlet |
Pressure dew point | +3 °C |
Power | 0.31 kW, 3.1 A, 230–240 V single phase |
Refrigerant | R134a |
Connections | G 1″ BSP female |
Size, weight | 420 × 350 × 740 mm, 40 kg |
Max. ambient / inlet temp | 45 °C / 55 °C |
Max. inlet pressure | 14 bar |
The older 2008 manual lists a different MD20 revision (430 W, 36 kg). Check the nameplate before relying on electrical or refrigerant data.
Documents
Mattei MD 6–810 user and maintenance manual (PDF) — operation §3.3.1, technical data §4.1, maintenance §6.1, MD20 drawings in the appendix
Mattei MD range catalogue (PDF) — MD20 on page 5
History
May 2022: installed, with the FM-0018C2 filter, replacing the failed Ceccato DLX22.
Autumn 2024: moved with the rest of the system to the current compressor room.
Not yet documented
Photo of the nameplate and controller
Which manual revision applies
Whether the
srvservice from May 2026 has been done