10 October 2026 — Sent away for service
The CoverPro and both Juki overlockers were reported away for service. The CoverPro was announced back on 27 October 2026.
Still to verify: work performed during the service.
8 February 2026 — Looper-thread incident resolved
A reported sewing problem progressed from puckering to no seam because the looper thread had escaped its eye. Restoring the threading resolved the incident.
Check the complete threading route before assuming a timing fault if similar symptoms recur.
Adding a maintenance entry
Record the date, symptom, work performed, parts used and result. Include useful photos and a source or contact for follow-up. Distinguish completed repairs from proposed work and confirm the result with an appropriate test.