Air compressor — Mattei ERC 507L

Recurring HIGH TEMP trips. The most recent was on 14 October 2026; restarting after cooling restored the air supply, but the cause is not fixed. See the maintenance log.

Oil-injected rotary-vane compressor supplying the compressed air system. Normally left running in AUTO.

Mattei ERC 507L

Mattei ERC 507L




Location

Compressor room, beside the storage room

Access

Maintainers only — Erik Cederberg, Daniel Berglund

Pressure

7.5 bar nominal, 8 bar max

Output

1.38 m³/min

Service

Aircenter AB, about once a year

Controls

Control panel (historical photo)

Control panel (historical photo)


Control

Function

Green START RUN / AVVIO MARCIA

Start

Red STOP / ARRESTO

Normal stop, with an unloading cycle

HIGH TEMP / ALTA TEMP lamp

Over-temperature trip

Blue TRIP RESET / BLOCCO

Reset after a trip

CONT. / AUTO selector

Keep in AUTO

Mushroom button

Emergency stop

Hour meter

Record at every service

In AUTO the motor stops and starts by itself with demand. A silent motor does not mean the compressor is off.

Stopping

Stopping the compressor cuts air to every room, so agree it with the maintainers first.

  1. Press STOP / ARRESTO.

  2. Wait for the motor to stop by itself, about two minutes of unloaded running.

  3. Only then switch off or isolate the power.

Cutting power, opening the cover or using the emergency stop while the motor runs can push oil into the intake filter. Use the emergency stop only in a real emergency, and report it afterwards.

The cover has an interlock that stops the motor immediately. It opens with a triangular key; press the cover into place when locking it.

HIGH TEMP trip

  1. Let the compressor cool and tell a maintainer.

  2. Check for blocked cooling, a hot room, leaks or unusually heavy air use (e.g. sandblasting).

  3. When a restart is agreed: TRIP RESET, then START RUN with AUTO selected.

  4. Don't keep resetting a fault that comes back, or one with abnormal noise or no pressure build-up.

Maintenance

  • Oil: Mattei Rotoroil F2 only. Check the level in the sight glass. Never open the filler while running or under pressure.

  • Interval: about yearly; the January 2022 service recommended every 2,500 running hours. The meter read 44,152 h in January 2022.

  • Cooling: keep vents and coolers clear.

  • Cyclone filter drain: timer-controlled, replaced April 2025.

  • Before any service: normal stop, isolate the power, prevent automatic restart, isolate from the air network and release the pressure. Qualified personnel only.

  • Maintenance and repair log

Specifications

Identification plate

Identification plate




Model

ERC 507 L

Serial number

B2908BR-2005

Year

2005

Motor

7.5 kW, 1,460 rpm

Pressure

7.5 bar nominal / 8 bar max

Output

1.38 m³/min

Weight

170 kg

Documents

Not yet documented

  • The exact manual and wiring diagram for serial B2908BR-2005